VALVOLINE INC -- PREMIUM STARTING FLUID -- 6850-00N023049
===================== Product Identification ===================== Product ID:PREMIUM STARTING FLUID MSDS Date:07/19/1989 FSC:6850 NIIN:00N023049 === Responsible Party === Company Name:VALVOLINE INC Box:14000 City:LEXINGTON State:KY ZIP:40512 Country:US Info Phone Num:800-274-5263 Emergency Phone Num:800-274-5263 CAGE:GO029 === Contractor Identification === Company Name:VALVOLINE INC Box:14000 City:LEXINGTON State:KY ZIP:40512 Phone:(606) 268-7000 CAGE:GO029 Company Name:VALVOLINE OIL CO Address:3499 BLAZER PKY Box:14000 City:LEXINGTON State:KY ZIP:40512 Country:US Phone:606-357-7206 / 800-274-5263 CAGE:72527 ============= Composition/Information on Ingredients ============= Ingred Name:CARBON DIOXIDE CAS:124-38-9 RTECS #:FF6400000 Fraction by Wt: 1-10% OSHA PEL:5000 PPM ACGIH TLV:5000PPM/30000STEL;93 Ingred Name:HEPTANE CAS:142-82-5 RTECS #:MI7700000 Fraction by Wt: 55-70% OSHA PEL:500 PPM/500 STEL ACGIH TLV:400 PPM/500STEL;9293 Ingred Name:ETHANE, 1,1'-OXYBIS-; (ETHYL ETHER). BP:94.0F,34.4C. VP:439 MMHG @ 68F. CAS:60-29-7 RTECS #:KI5775000 Fraction by Wt: 25-40% OSHA PEL:400 PPM;500 PPM STEL ACGIH TLV:400 PPM;500 PPM STEL EPA Rpt Qty:100 LBS DOT Rpt Qty:100 LBS Ingred Name:HEXANE CAS:110-54-3 RTECS #:MN9275000 Fraction by Wt: 1-10% OSHA PEL:500 PPM ACGIH TLV:50 PPM; 9293 EPA Rpt Qty:1 LB DOT Rpt Qty:1 LB ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE:SKIN:PRLNG/RPTD CONTACT MAY CAUSE MOD IRRIT, DEFAT, DERM. EYES:MAY CAUSE SEVERE IRRIT, REDNESS, TEARING, BLURRED VISION. INGEST:MAY CAUSE GI IRRIT, NAUS, VOMIT & DIARR. ASPIR OF MATL INTO LUNGS MAY CAUSE CHEM PNEUMONIA WHICH MAY BE FATAL. INHAL:EXCESSIVE INHAL OF VAPS MAY CAUSE NASAL & RESP (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:IRRIT, CNS EFFECTS INCLUDING DIZZ, WEAKNESS, FATG, NAUS, HDCH & POSSIBLE UNCON & EVEN ASPHYXIATION. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:SKIN:THORO WASH EXPOSED AREA W/SOAP & H*2O. REMOVE CONTAM CLTHG & LAUNDER BEFORE REUSE. EYES:FLUSH W/LG AMTS OF H*2O FOR @ LST 15 MIN, LIFTING UPPER & LOWER LIDS OCCAS, GET MD. INGEST:DO NOT INDUCE VO MIT, KEEP PERS WARM & QUIET & GET MD. ASPIR OF MATL INTO LUNGS DUE TO VOMIT CAN CAUSE CHEM PNEUM WHICH CAN BE FATAL. INHAL:REMOVE INDIVIDUAL TO FRESH AIR. IF BRTHG DFCLT, ADMIN O*2. IF BRTHG (SUPDAT) ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:<-58F,<-50C Lower Limits:1% Extinguishing Media:REGULAR FOAM OR CO*2 OR DRY CHEMICAL. Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED POSITIVE PRESSURE DEMAND SCBA & FULL PROTECTIVE EQUIPMENT. . Unusual Fire/Explosion Hazard:NEVER USE WELDING/CUTTING TORCH ON/NEAR DRUM (EVEN EMPTY) BECAUSE PROD (EVEN JUST RESIDUE) CAN IGNITE EXPLOSIVELY. ================== Accidental Release Measures ================== Spill Release Procedures:SM SPILL:ALLOW TO EVAPORATE. VENT AREA. ELIM ALL SOURCES OF IGNIT SUCH AS FLARES, FLAMES (INCL PILOT LIGHTS) & ELEC SPKS. LG SPILL:ELIM ALL IGNIT SOURCES (FLARES, FLAMES, INCL PILOT LIGHTS, ELEC SPKS) . ALLOW TO EVAP. PERSONS NOT WEARING PROT (SUPDAT) Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER. Other Precautions:CNTNRS OF MATL MAY BE HAZ WHEN EMPTIED. SINCE EMPTIED CNTNRS RETAIN PROD RESIDUES (VAP, LIQ &/OR SOLID), ALL HAZ PRECS GIVEN IN THIS MSDS MUST BE OBSERVED. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF WORKPLACE EXPOS LIMIT OF PROD/ANY COMPONENT IS EXCEEDED, NIOSH/MSHA APPRVD AIR SUPPLIED RESP IS ADVISED IN ABSENCE OF PROPER ENVIRON CONTROL. OSHA REGS ALSO PERMIT OTHER NIOSH/MSHA APPRVD RESPS (NE G PRESS TYPE) UNDER SPECIFIED (SUPDAT) Ventilation:PROVIDE SUFFICIENT MECH (GEN &/OR LOC EXHST) VENT TO MAINTAIN EXPOSURE BELOW TLV. Protective Gloves:NOT REQUIRED UNDER NORMAL CNDTNS OF USE. Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:NOT REQUIRED UNDER NORMAL CONDITIONS OF USE. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health FIRST AID PROC:HAS STOPPED GIVE ARTF RESP. KEEP PERS WARM, QUIET & GET MD. SPILL PROC:EQUIP SHOULD BE EXCLUDED FROM AREA UNTIL LEAK HAS BEEN REPAIRED. RESP PROT:CONDITIONS. ENGINEERING OR ADMINISTRATI VE CONTROLS SHOULD BE IMPLEMENTED TO REDUCE EXPOSURE. ================== Physical/Chemical Properties ================== HCC:G2 Boiling Pt:B.P. Text:SEE ING 3 Vapor Pres:SEE ING 3 Vapor Density:HVR/AIR Spec Gravity:< H*2O Evaporation Rate & Reference:SLOWER THAN ETHER Appearance and Odor:COMP GAS Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES AVOID CONTACT W/STRONG OXIDIZING AGENTS. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS; CO*2 & CO, VARIOUS HYDROCARBONS, ETC. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULTATIONS . SM SPILL:ALLOW MATL TO EVAPORATE. LG SPILL:VENTILATE AREA OF SPILL. ALLOW MATL TO EVAPORATE. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.